The PCE-P50 is a differential pressure manometer developed by PCE Instruments, designed to accurately measure and record differential pressure in various industrial, laboratory, and HVAC applications. This particular model is well-suited for tasks that require precise monitoring of pressure differences to ensure optimal operation and safety standards.
With its data logging capabilities and easy-to-use design, it is particularly useful for HVAC technicians, industrial process controllers, and laboratory personnel. Its functionality ensures that it can be applied in a variety of settings, providing critical data that helps in maintaining operational efficiency and safety.
| Pressure Meter |
Parameter | PCE-P50 | |
| Max. Pressure |
positive/ negative or overpressure / vacuum |
150 psi | |
| PSI | Range | 0…±100 | |
| Resolution | 0.1 | ||
| mbar | Range | 0…±6900 | |
| Resolution | 4 | ||
| inH20 | Range | 0…±2750 | |
| Resolution | 2 | ||
| inHg | Range | 0…±200 | |
| Resolution | 0.1 | ||
| mmHg | Range | 0…±5200 | |
| Resolution | 3 | ||
| kPa | Range | 0…±690 | |
| Resolution | 0.4 | ||
| cmH20 | Range | 0…±7000 | |
| Resolution | 4 | ||
| Kg/cm² | Range | 0…±7 | |
| Resolution | 0.004 | ||
| Data format | Baud rate: 2400 baud,1 stop bit, 8 data bits | ||
| Accuracy | ±0.3 % (full range, @ +25°C / +77°F) | ||
| Repeatability | ±0.2 % (max. ±0.5 % of full scale) | ||
| Duration | 0.3 ms | ||
| Operating temperature max | +50 °C / +122 °F | ||
| Power supply | 9 V DC / power converter (optional) | ||
| 1 x 9 V – block battery PP3 | |||
| Dimensions | 182 x 72 x 30 mm / 7.1 x 2.8 x 1.1″ | ||
| Weight | 150 g / 5.3 oz | ||