The Fluke 1777 Three-Phase Power Quality Analyzer is a state-of-the-art instrument designed to simplify power quality logging, troubleshooting, and analysis. It is engineered to be a faster and easier way to perform power quality studies, offering automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. This article will provide an in-depth overview of the Fluke 1777, discussing its key features, applications, and benefits.
The Fluke 1777 offers a range of features that make it a versatile and reliable tool for power quality analysis. Some of its key features include:
The Fluke 1777 is suitable for a wide range of applications, including:
The Fluke 1777 analyzer is a powerful tool that can be used to perform basic and advanced power quality studies on electrical systems. It provides an overview of the overall health of an electrical system by measuring fundamental power quality variables.
In addition to basic power studies, users can leverage the Fluke 1777’s capabilities to perform more in-depth power quality analysis such as harmonic surveys and load testing. This can help identify potential issues and areas for improvement.
The Fluke 1777 can also be used to conduct energy surveys, making it a valuable tool for energy audits and efficiency projects. By analyzing power quality data, users can identify patterns of energy consumption and take appropriate corrective actions.
If you are experiencing nuisance circuit breaker tripping, the Fluke 1777 can help you identify the root cause of the issue and take corrective actions.
This analyzer is also suitable for conducting power quality surveys in utility settings, helping to ensure the reliability and stability of the power grid.
Finally, the Fluke 1777 can be used to capture and analyze high-speed transients, which can help identify and resolve equipment failures.
The Fluke 1777 is a reliable and accurate tool for data capture, ensuring that users collect precise data for their power quality studies. It has an automatic measurement capture system and best-in-class accuracy. It is also convenient and easy to use with a straightforward user interface and can power directly from the measurement circuit. The Fluke 1777 is versatile and adaptable, suitable for basic power studies to advanced power quality analysis, making it a valuable tool for electrical professionals.
Its future-proof design meets the future requirements of Class A edition 4, EN 50160, and IEEE 519 standards, ensuring users are ready to tackle tomorrow’s measurement requirements, today. Additionally, the Fluke 1777 comes with Fluke Energy Analyze Plus software, which allows users to create customized reports or leverage built-in one-click reporting to industry standards like EN 50160, IEEE 519, and GOST 33073.
Parameter | Range | Resolution | Intrinsic Accuracy at Reference Conditions % of Reading + % of Full Scale | |
Voltage | 1000 V | 0.1 V | 0.1 % of nominal voltage in accordance with IEC 61000-4-30 Class A ±(0.04 % + 0.004 %) | |
Voltage dips and swells | – | 0.1 V | 0.2 % of Vnom | |
Voltage transients | ±8 kVpk | – | ±5 % +0.25 % | |
Voltage harmonics/interharmonics | 100% | 0.1 % / 0.1 mV | ≥1 % Vnom1: ±2.5 % of rdg., <1 % Vnom: ±0.025 Vnom | |
THD on voltage | 100% | 0.1 % / 0.1 V | ±(2.5 % + 0.5 %) | |
Voltage distortions 2-9 kHz | Max 100 V | 0.1 mV | ±(2.5 % + 0.1 V) | |
Voltage distortions 9-30 kHz | Max 100 V | 0.1 mV | ±(2.5 % + 0.1 V) | |
Current (Rogowski clamp mode) | With iFlex 1500 A, | 150 A | 0.01% | ±(1 % + 0.02 %) |
i17XX-FLEX1500 24 | 1500 A | 0.1 A | ||
With iFlex 3000 A, | 300 A | 0.01 A | ±(1 % + 0.03 %) | |
i17XX-FLEX3000 24 | 3000 A | 0.1 A | ||
With iFlex 6000 A, | 600 A | 0.1 A | ±(1.5 % + 0.03 %) | |
i17XX-FLEX6000 36 | 6000 A | 0.04 | ||
With AC clamp 40 A, | 0.17 | 0.001 A | ±(0.7 % + 0.02 %) | |
i40s-EL | 40 A | 0.01 A | ||
With AC clamp 400 A, | 40 A | 0.01 A | ±(2 % + 0.2 %) | |
i400s-EL | 400 A | 0.1 A | ±(0.7 % + 0.1 %) | |
With AC/DC clamp | 200 A | 0.01 A | ±(0.8 % + 0.2 %) | |
2000 A, 80i-2010s-EL | 2000 A | 0.1 A | ||
Current min/max | 100% | defined by accessory | x2 of intrinsic accuracy | |
Current harmonics/interharmonics | 100% | 0.1 % / 0.01 A | ≥3 % Inom: ±2.5 % of rdg., <3 % Inom: ±0.15 % of Inom | |
THD on current | 100% | 0.10% | ±(2.5 % + 0.5 %) | |
Frequency | 42.5 Hz … 69 Hz | 0.001 Hz | ±0.01 Hz | |
Voltage unbalance | 100% | 0.10% | ±0.15 % | |
Current unbalance | 100% | 0.10% | ±0.15 % | |
Flicker Pinst, Pst, Plt | 0 to 20 | 0.01 | 5% | |
Mains signaling voltage | Up to 3 kHz | 0.1 V / 0.1 % | 1-3 % Vnom: ±0.15 % of Vnom, 3-15 % Vnom: ±5 % of rdg. | |
0-15 % of Vnom | ||||
AUX input | ±10 V | 0.1 mV | ±(0.2 % + 0.05 %) |
Parameter | Direct Input1 | Clamp i40S-EL |
Power range W, VA, var | Clamp: 50 mV / 500 mV | 4 A / 40 A |
Rogowski: 15 mV / 150 mV | ||
Clamp: 50 W / 500 W | 4k W / 40 kW | |
Rogowski: 15 W / 150 W | ||
Max. resolution W, VA, var | 0.1 W | 1 W / 10 W |
Phase (voltage to current) | ±0.2° | ±1° |
Calibration cycle | 2 years |
Size (L X W X HD) | 28.0 cm x 19.0 cm x 6.2 cm (11.0 in x 7.5 in x 2.4 in) |
Weight | 2.1 kg (4.6 lb) |
Anti-theft protection | Slot to support Kensington lock |
Operating temperature range | -10 °C to 50 °C |
Storage temperature range | -20 °C to 60 °C |
Operating humidity | IEC 60721-3-3: 3K5, modified: |
-10 °C to 30 °C: ≤95 %, no condensation or ice | |
35 °C: 70 % | |
40 °C: 55 % | |
50 °C: 35 % | |
IP Rating | IEC 60529: IP50 |
Vibration | IEC 60721-3-3 / 3M2 |
General | IEC 61010-1: Pollution Degree 2 |
Power supply | Overvoltage Category IV 600 V With Mains Adapter MA-C8: Overvoltage Category II 300 V |
Measurement | IEC 61010-2-030: CAT IV 600 V, CAT III 1000 V |
Altitudes 2000 m to 4000 m | Derate to: Power Supply: Category IV 300 V With MA-C8 Adapter: Category II 150 V Measurement: CAT IV 300 V, CAT III 600 V, CAT II 1000 V |