PCE-HVAC 2
Multipurpose manometer is one of the pressure measuring devices used in various industries. This device works electronically and has the ability to measure different pressures.
Up to 99 measurement values can be stored in each bank for air speed measurements up to 80 m/s (178.66 mph), Zero, Min, Value, Size, Functions, and Hold.
A high-velocity multifunction manometer with a pitot tube is called PCE-HVAC 2. This portable manometer may be used to measure ambient temperature, air pressure, differential pressure, and air flow. With the use of a pitot tube, measurements may be taken in tight locations such as small pipe networks.
The user can precisely observe the pressure on this device’s screen thanks to its electronic display. Different measurement units are available for some types of this apparatus, including those for load pressure, freezer pressure, oil pressure, wind pressure, liquid pressure, etc.
This device’s use is fairly straightforward; you simply attach it to the selected measuring point and turn it on. The apparatus then gauges the pressure and displays the outcome on the screen.
ssure | |
Accuracy | ± 0.3% of reading at 25°C / 77°F |
Repeatability | ± 0.2% (± 0.5% of reading) |
Linearity / hysteresis | ± 0.29% of reading |
Pressure range | 5000 Pa |
Maximum pressure | 10 psi |
Response time | Typically 0.5 seconds |
Measuring range | 0.7252 psi |
50.00 mbar | |
20.07 inH2O | |
509.8 mmH2O | |
5000 Pa | |
Resolution | 0.0001 psi |
0.01 mbar | |
0.01 inH2O | |
0.1 mmH2O | |
1 Pa | |
Selectable units | Mbar, psi, inH2O, mmH2O, or Pa |
Air speed | |
Measuring range | 1 … 80 m / s |
200 … 15733 ft / min | |
3.6 … 288 km / h | |
2.24 … 178.66 MPH | |
2 … 154.6 knots | |
Resolution | 0.01 m / s |
1 ft / min | |
0.1 km / h | |
0.01 MPH | |
0.1 knots | |
Accuracy | At m / s: ± 2.5% of measured value |
At ft / min, Km / h, MPH and Node: Depending on the air speed and the size of the air duct | |
Flow rate | |
Measuring range | 0 … 99999 m³ / min |
0 … 99999 ft³ / min | |
Resolution | 0.001 … 100 m³ / min |
0.0001 … 100 ft³ / min | |
Temperature | |
Measuring range | 0 … 50°C / 32 … 122°F |
Resolution | 0.1°C / 0.18°F |
Accuracy | ± 1°C / ± 1.8°F |
General | |
Diameter of pitot tube | 8 mm / 0.3 in |
Length of measuring hoses | Each 85 cm / 33.46 in |
Total length of the tube | 335 mm / 13.18 in |
Low battery indicator | Yes |
Power supply | 9V block battery |
Operating conditions | 0 … 50°C / 32 … 122°F / <90% RH non-condensing |
Storage conditions | -10 … 60°C / 14 … 140°F / <90% RH non-condensing |
Internal memory | 99 measured values per parameter |
Interface | USB |
Display | LCD |
Housing material | ABS plastic |
Dimensions | Device: 206 x 95 x 45 mm / 8.11 x 3.7 x 1.7 in |
Pitot tube: 335 mm / 13.18 in – Ø 8 mm / 0.31 in | |
Weight (incl. pitot tube, battery and measuring hoses) | 600 g / 1.3 lbs |