The Fluke 719Pro 300G Electric Pressure Calibrator is designed for one-handed operation and can calibrate pressures up to 300 psi (20 bar). It’s particularly useful for calibrating high-accuracy transmitters, pressure switches, and gauges. The device features an integrated electric pump, a precision pressure adjust vernier for fine adjustments, and a switch test function for checking pressure switches.
The Fluke 719Pro 300G offers excellent accuracy, with a pressure measurement uncertainty of 0.025% and the ability to measure and source mA with 0.015% accuracy. It’s equipped with a large backlit screen that displays multiple parameters simultaneously and has a robust design suited for various industrial applications like petro-chemical, oil and gas, and more. The device also includes inputs for mA, voltage, switch contacts, and an optional RTD probe for temperature measurements.
Measurement | |||
Fluke-719Pro-30G | Range | -12 to 30 psi / -0.8 to 2 bar | |
Resolution | 0.001 psi / 0.0001 bar | ||
Fluke-719Pro-150G | Range | -12 to 150 psi / -0.8 to 10 bar | |
Resolution | 0.01 psi / 0.001 bar | ||
Fluke-719Pro-300G | Range | -12 to 300 psi / -0.8 to 20 bar | |
Resolution | 0.01 psi / 0.001 bar | ||
Accuracy | ±0.025% of full scale, 6 months ±0.035% of full scale, 1 year |
||
Temperature effect (all ranges) | Add ±0.002% F.S./°C for temps outside of 15°C to 35°C | ||
Dry air and non-corrosive gas only No effect on accuracy on all functions from 15°C to 35°C |
|||
Function | Range | Resolution | Accuracy (1 year) |
mA DC (simulation and measurement) | 0-24 mA DC | 0.001 mA | ±0.015% of reading ±2 counts |
1000 ohm maximum load in mA source, 26 V DC maximum voltage in mA simulate | |||
Volts DC (measurement only) | 30 V DC | 0.001 V | ±0.015% of reading ±2 counts |
No AC voltage measurement, do not exceed 30 V DC | |||
Temperature (measurement only, Pt100 RTD) | -50 to 150°C (-50°F to 302°F) |
0.01°C 0.01°F |
Temperature ±0.1°C (0.2°F) |
±0.25°C (±0.45°F) combined uncertainty when using 720 RTD probe (optional accessory) | |||
Loop power supply | 24 V DC | N/A | 24 mA at 24 V |
Temperature effect (all functions) | – | – | Add ±0.002% F.S./°C for temps outside of 15°C to 35°C |
No effect on accuracy on all functions from 15°C to 35°C | |||
Environmental | |||
Operating temperature | -10°C to +50°C | ||
Storage temperature (with batteries) | Per battery manufacturer’s specification within storage specification below | ||
Storage temperature (without batteries) | -20°C to +60°C | ||
Power Requirements | |||
Battery | Eight (8) standard Alkaline AA batteries | ||
Battery life | 300 pump cycles to 150 psi minimum; 1000 pump cycles to 30 psi; 100 pump cycles to 300 psi minimum | ||
Physical | |||
Dimensions (H x W x D) | 24.13 x 11.18 x 7 cm (9.5 x 4.4 x 2.8 in) | ||
Weight | With holster 1.2 kg (2.5 lb) | ||
Connections | |||
Pressure | 1/8 inch female NPT | ||
Electrical | Standard banana jacks | ||
RTD | 4 pin miniature circular | ||
External module | 6 pin miniature circular | ||
Engineering Units (Configurable) | |||
psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F |